57
AIEWMember Electrical Product Catalogue Issue 17
Special Selection
A rigid structure which supports and feeds lighting, in single phase
or three phase.
Conforms to BS EN 60439-2
Conductors are protected by an auto-extinguishing sheath. Body
is hot dip galvanised steel to BS EN 10142, which forms the
protective earth.
IP55 (according to BS EN 60529)
Trunking lengths
Lengths with 2 or 3 tap-off outlets (spaced every
1.0m) are supplied with outlet covers fitted.
Lengths with 6 tap-off outlets (spaced every 0.5m) are
supplied with 3 tap-off covers fitted.
With 3 + 3 outlets
Tap-off outlets are spaced every 1·0m on both sides (6 positions per 3m length)
With 5 outlets on one side
Suitable for rising mains
Without outlets
Feeder lengths. A tap-off point is only possible on the junction between two lengths
Trunking lengths – 3 m
For vertical runs or riser applications. Special lengths between 400mm and 3m are available upon request.
IP40 protection when installed with outlets facing up. IP52 protection when
installed edgeways. IP55 protection when using tap-off outlet covers and
appropriate accessories.
Flame retardant in compliance with IEC 60332-3. Fully compliant with
BS EN 60439-2.
Rated currents are at an average ambient temperature of 40
º
C (over and
above the required standard of 35
º
C).
LIGHT DUTY
LB SINGLE SIDED LIGHTING BUSBAR
Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality
galvanised steel suitable for use as a protective earth.
IP40 as standard, increasing to IP55 with use of appropriate accessories.
63 A
Cat. Nos
Length
(m)
Outlet
points
Weight
(kg)
51530101 3 3 + 3 7.890
51530116 2 2 + 2 5.260
51530115 1.5 1 + 1 3.945
51530114 1 1 + 1 2.630
51530112 < 1.5 –
–
51530113 > 1.5 –
–
Trunking lengths
Tap-off outlets are spaced every 1.0 m on both sides and are fitted with shutters
to prevent accidental contact with live parts.
Expansion joints are not required.
Available in 100A and 160A with Fire Barrier / with Thrust unit
LOWAND MEDIUM POWER 63/100/160A
MS DOUBLE SIDED BUSBAR
MEDIUM POWER 160 - 1000A
MR MEDIUM RATING BUSBAR
Complete range available
ask for details of accessories and components or
for a competitive quote
63 A with fire barrier
For vertical runs or riser applications exceeding 20m
Lengths are fitted with a fire barrier and are used
to pass through fire-resistant walls
In accordance with DIN 4102-9 and EN 1366-3
63 A with thrust unit
For vertical runs or riser applications exceeding 20m
51530131
3 3 + 3 7.990
51530141
3 3 + 3 7.890
Aluminium Copper
Rating (A)
Weight (kg)
Copper Aluminium
50400101
160
19.9
–
50400102 55400102 250
20.9
25.7
50400103 55400103 315
22.8
28.1
50400104 55400104 400
33.8
36.9
50400108
500
37.5
–
50400105 55400105 630
41.7
56.0
50400106 55400106 800
44.3
72.1
55400107 1000
–
83.7
50400251
160
19.9
–
50400252 55400252
250
20.9
25.7
50400253 55400253
315
22.8
28.1
50400254 55400254
400
33.8
36.9
50400258
500
37.5
–
50400255 55400255
630
41.7
56.0
50400256 55400256
800
44.3
72.1
55400257 1000
–
83.7
Aluminium Copper
Rating (A)
Weight (kg)
Copper Aluminium
50400241
160
19.9
–
50400242 55400242 250
20.9
25.7
50400243 55400243
315
22.8
28.1
50400244 55400244 400
33.8
36.9
50400248
500
37.5
–
50400245 55400245 630
41.7
56.1
50400246 55400246 800
44.3
72.1
55400247 1000
–
83.7